Hafler 0915P Stereo Amplifier User Manual


 
GENERAL
j
INPUTS: Tuner, Video, CD, Phono/Aux 1, Aux 2, Tape Monitor
INFORMATION
INSTALLATION
OUTPUTS: Out
1,
Out 2, Record Out, Headphone
CONTROLS: input Selector, Volume, Tape Monitor , Tone Control In, Balance, Bass, Treble,
Output Off, Power, Phono MM/MC
INDICATORS: Mute/Standby, Power
CONVENIENCE OUTLETS: 1 Unswitched, 4 Switched (Polarized)
(Convenience Outlets are not included on 200-240 VAC units)
PHYSICAL DIMENSIONS:
17”
(W) x 7-5/8” (D) x
l-3/4”
(H) (excluding feet); Faceplate 17” or 19” (W).
43.2cm (W) x 19.4cm (D) x 4.5cm (H) (excluding feet); Faceplate 43.2cm or
483cm
(W).
POWER CONSUMPTION (Excluding Convenience Outlets): 9 watts Max.
AC LINE VOLTAGE OPERATING RANGE: (exceeding lower limit will activate muting circuit;
exceeding upper limit will result in overheating and/or component damage)
100
-
120 Volt 50/80 Hz Models: 85
-
130 volts
200
-
240 Volt 50/80 Hz Models: 170
-
280 volts
RACKMOUNTING
VENTllATlON/
PLACEMENT
LINE VOLTAGE
The 915 Preamplifier is supplied in either a 17” Black Version, or a 19” Silver Version. The 19
model has rackmounting holes provided for installation in equipment racks. The holes are on
standard EIA spacings.
The 915 produces very little heat during operation, and therefore requires no special consider-
ations for ventilation. The preamplifier should be located at least several inches away from
components that contain large power transformers (such as power amplifiers), due to the
possibility of audible hum or buzz from magnetic radiation.
The 915 Preamplifier is configurable for either 100
-
120 volt, or 200
-
240 volt operation. This
is accomplished by changing internal jumpers on the printed circuit board. The procedure is
detailed in the section “CHANGING LINE VOLTAGE RATING”. Make sure that the unit is
configured for your local AC line voltage before attempted use. The configuration is labelled
directly above the power cord connector.
OPERATION/CONNECTIONS
POWER CORD
CONNECTION
INITIAL POWER-
UP/MUTING
SYSTEM
Units wired for200-240 VACare supplied without power cords. Local agents will supply cords with
male connectors appropriate to the local standard.
Units wired for
100-120
VAC are supplied with a detachable AC power cord. The female
connector plugs into the receptacle provided on the rear panel. This power cord is a standard
IEC Type 320, 3-wire, 18 gauge assembly. Should replacement ever be necessary, be sure to
replace it with an identical cord.
Never remove the grounding pin from the male end of the cord.
In applications where a grounded
wall outlet is not available, a ground adaptor should be employed, with the ground tab or wire of
the adaptor connected to a suitable earth ground.
For units wired for 200-240 VAC, the front panel Power Switch controls the power to the
Preamplifier’s circuitry. If desired, this switch may be left “on” at all times to allow circuits to be
thermally stabilized for maximum fidelity as soon as the system is used.
-5-
IEC Type 320, 3-wire, 18 gauge