DA AV EQ Series • Installation and Rear Panel
DA AV EQ Series • Installation and Rear Panel
Installation and Rear Panel
2-3
3. Mechanical loading — Mount the equipment in the rack
so that a hazardous condition is not achieved due to
uneven mechanical loading.
4. Circuit overloading — Connect the equipment to the
supply circuit and consider the effect that circuit
overloading might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this
concern.
5. Reliable earthing (grounding) — Maintain reliable
grounding of rack-mounted equipment. Pay particular
attention to supply connections other than direct
connections to the branch circuit (e.g., use of power strips).
Rack mounting procedure
To mount the distribution amplifier on a 6" deep or 9.5" deep
rack shelf,
1. If rubber feet were previously attached to the bottom of
the unit, remove them.
2. Mount the unit on the rack shelf, using two 4-40 x 3/16"
screws in opposite (diagonal) corners to secure it.
3. Install blank panel(s) or other unit(s) on the rack shelf.
4. Attach the rack shelf to the rack using the supplied bolts.
6" Deep Rack Shelf
Front false
faceplate
uses 2
screws.
1/2 Rack Width Front False
Faceplate
Use the 2 mounting holes on
opposite corners.
(2) 4-40 x 3/16"
Screws
Mounting a DA AV EQ on a 6" deep rack shelf
Mounting the DA AV EQ Series
The DA AV EQ distribution amplifiers can be set on a table;
mounted on a rack shelf; or mounted through or under a desk,
podium, or tabletop.
The following optional mounting kits are available for the
DA AV EQ Series:
RSB 126 1U, 6" deep basic rack shelf (part #60-604-10)
RSU 126 1U, 6" deep universal rack shelf kit
(part #60-190-10)
RSB 129 1U, 9.5" deep basic rack shelf (part #60-604-01)
RSU 129 1U, 9.5" deep universal rack shelf kit
(part #60-190-01)
MBU 125 under-desk mounting bracket kit
(part #70-077-01)
MBD 129 through-desk mounting bracket kit
(part #70-077-02)
Tabletop use
Four self-adhesive rubber feet are included with the unit. For
tabletop use, affix one foot at each corner of the bottom of the
DA, and place the unit in the desired location.
Rack mounting
UL rack mounting requirements
The following Underwriters Laboratories (UL) requirements
pertain to the safe installation of the equipment in a rack.
1. Elevated operating ambient temperature — If the
equipment is installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack
environment may be greater than room ambient
temperature. Therefore, install the equipment in an
environment compatible with the maximum ambient
temperature (Tma = +113 °F, +45 °C) specified by Extron.
2. Reduced air flow — Install the equipment in a rack so that
the amount of air flow required for safe operation of the
equipment is not compromised.
2-2