10 Micro Motion
®
Series 3000 Transmitters and Discrete Controllers
Model 3100 accessory
Model 3500/3700 liquid flow performance
Relays module Three relays
Solid state, SPST
Rated at 24–250 VAC, 40 mA to 5 A; or 0–70 VDC, 5 A
Energized by discrete outputs
NEMA 4X (IP65) enclosure (optional)
UL and CSA approvals Class I, Div. 2, Groups A, B, C, and D
ATEX approvals Suitable for installation in Zone 2, when properly installed in a suitable enclosure, complying with
ATEX Directive (94/9/EC) for Group II, Category 3G, according to CENELEC standard EN 50021
(1998) and marked as:
EEx n V II T4
KEMA 97 ATEX4940X
Ambient temperature –20 to +60 °C (–4 to +140 °F)
Additional installation-specific requirements are described in detail in the Series 3000 instruction
manual.
Sensor model
Mass flow accuracy
(1)(2)
(1) Stated flow accuracy includes the combined effects of repeatability, linearity, and hysteresis.
(2) For the details of flow accuracy and repeatability specifications, refer to the product data sheet for each sensor family.
ELITE
®
±0.05% of rate
F-Series ±0.10% of rate
H-Series ±0.10% of rate
T-Series ±0.15% of rate
R-Series ±0.50% of rate
Volume flow accuracy
(1)(2)
ELITE ±0.05% of rate
F-Series ±0.15% of rate
H-Series ±0.15% of rate
T-Series ±0.25% of rate
R-Series ±0.50% of rate
Repeatability
(2)
ELITE ±0.025% of rate
F-Series ±0.05% of rate
H-Series ±0.05% of rate
T-Series ±0.05% of rate
R-Series ±0.25% of rate