Power consumption is direct proportional for other mains voltages. The following conversion factors are meant for easy
conversion: 100V = 2.3; 120V = 1.9; 240V = 0.96
1) P
d
= Power Dissipation
2) 1 BTU = 1055.06 J = 1055.06 Ws
3) Sine Signal Modulation (1 kHz)
4) Pink Noise according to EN60065 / 7. Edition
5) 10% Mains Over Voltage
CPS2.9
U
mains
in V I
mains
in A P
mains
in W P
out
in W
P
d
in W
1
BTU/hr
2
Idle
230 0.4 46 0 46 157
Max. Output Power @ 8 Ω
3
230 9.4 1740 1100 640 2184
Max. Output Power @ 4 Ω
3
230 15.3 2810 1800 1010 3446
1/3 Max. Output Power @ 4 Ω
3
230 8.7 1450 600 850 2900
1/8 Max. Output Power @ 4 Ω
3
230 3.6 560 225 335 1143
1/8 Max. Output Power @ 4 Ω
4
230 3.6 540 225 315 1075
1/8 Max. Output Power @ 4 Ω
4 5
253 4.1 690 275 415 1416
Normal Mode (-10 dB) @ 4 Ω
3
230 3.2 460 160 300 1024
Rated Output Power (0 dB) @ 4 Ω
3
230 14.4 2640 1600 1040 3549
Alert (Alarm) Mode (-3 dB) @ 4 Ω
3
230 10.2 1770 800 970 3310
Max. Output Power @ 2 Ω
3
230 21.6 4090 2800 1290 4402
1/8 Max. Output Power @ 2 Ω
3
230 5.1 850 350 500 1706
1/8 Max. Output Power @ 2 Ω
4
230 5.0 810 350 460 1570
CPS2.12
U
mains
in V I
mains
in A P
mains
in W P
out
in W
P
d
in W
1
BTU/hr
2
Idle
230 0.5 57 0 57 194
Max. Output Power @ 8 Ω
3
230 12.2 2100 1500 600 2047
Max. Output Power @ 4 Ω
3
230 19.7 3620 2400 1220 4163
1/3 Max. Output Power @ 4 Ω
3
230 11.2 1900 800 1100 3753
1/8 Max. Output Power @ 4 Ω
3
230 4.7 720 300 420 1433
1/8 Max. Output Power @ 4 Ω
4
230 4.7 705 300 405 1382
1/8 Max. Output Power @ 4 Ω
4 5
253 5.3 880 375 505 1723
Normal Mode (-10 dB) @ 4 Ω
3
230 4.1 625 220 405 1382
Rated Output Power (0 dB) @ 4 Ω
3
230 18.9 3340 2200 1140 3890
Alert (Alarm) Mode (-3 dB) @ 4 Ω
3
230 13.4 2330 1100 1230 4197
Max. Output Power @ 2 Ω
3
230 27.5 5165 3600 1565 5340
1/8 Max. Output Power @ 2 Ω
3
230 10.5 1810 450 1360 4640
1/8 Max. Output Power @ 2 Ω
4
230 10.2 1730 450 1280 4368