MAINS OPERATION & RESULTING POWER AMP TEMPERATURES
The following tables are useful in determining power supply and cabling requirements.
The power drawn from the mains network is converted into acoustic output to feed the connected
loudspeaker systems plus heat. The difference between drawn power and dispensed power is referred to
as leakage power or dissipation (P
d
). The amount of heat resulting from power dissipation might remain
inside of a rack-shelf and needs to be diverted using appropriate measures. The following table is meant
as auxiliary means for calculating temperatures inside of rack-shelf systems/cabinets and the ventilation
efforts necessary.
The column “Pd” lists the leakage power in relation to different operational states. The column “BTU/hr”
shows the dispensed heat amount per hour.
MAINS OPERATION & RESULTING
CP3000S
U
mains
[V]
I
mains
[A]
P
mains
[W]
P
out
[W]
Pd
(5)
[W]
BTU/hr
(1)
idle
230 0.8 80 - 80 273
Max. Output Power @ 8
(1)
230 11.0 1780 2 x 600 580 1980
Max. Output Power @ 4
(1)
230 19.5 3240 2 x 1100 1040 3549
1/3 Max. Output Power @ 4
(1)
230 11.3 1740 2 x 366 1008 3439
1/8 Max. Output Power @ 4
(1)
230 4.6 640 2 x 137 366 1249
1/8 Max. Output Power @ 4
(2)
230 6.0 850 2 x 137 576 1965
1/8 Max. Output Power @ 4
(2),(4)
253 6.1 950 2 x 166 618 2109
Normal Mode (-10dB) @ 4
(1)
230 4.2 580 2 x 110 360 1230
Rated Output Power (0dB) @ 4
(1)
230 17.6 2860 2 x 900 1060 3617
Alert (Alarm) Mode (-3dB) @ 4
(1)
230 12.6 1980 2 x 450 1080 3685
Max. Output Power @ 2
(1)
230 30.3
(6)
5280 2 x 1600 2080 7100
1/8 Max. Output Power @ 2
(1)
230 7.0 1030 2 x 200 630 2150
1/8 Max. Output Power @ 2
(2)
2308.4 12502 x 2008502900
(
1) Sine Modulation (1kHz) (2) VDE-Noise (3) 1BTU = 1055.06J = 1055.06Ws
(4) 10% Mains Over Voltage (5) Pd = Leakage Power (6) Overload Detection is activatet
after 10s
The following factors allow direct proportional calculation of the mains current Imain for different mains
supply voltages: