Electro-Voice CP3000S Stereo Amplifier User Manual


 
8
9
REAR PANEL
Power amp output connection for the
two channels A (left) and B (right) is
provided via professional SPEAKON
connectors.
These offer an electrical and
mechanical secure connection which
complies to all security regulations.
It also allows the use of high quality
speaker cables with a diameter of
4 x 2.5 mm
2
. The EV accessory
assortment includes recommended
cables and connectors.
POWER AMPLIFIER OUTPUT CONNECTORS
BRIDGED MODE
With the BRIDGED-MODE switch being engaged, using the channel A input
for audio signal feed is mandatory, since input B provides no function. While
the amplier of channel A operates as usual. Additionally, the audio signal is
internally inverted and routed to the amplier of channel B. Both amps – A
and B – now work in push-pull operation to provide doubled output voltage at
the BRIDGED-OUT connector.
The regular output voltage of each amplier channel A + B is still present at the corresponding output
connectors CHANNEL A and CHANNEL B. However, using these signals is not recommendable because
of the aforementioned phase inversion. Operating the power amp in Bridged Mode with loads
of 2ohms connected is not allowable.
CAUTION: Operating the power amplier in Bridged-Mode may result in extremely high voltages
being present at the BRIDGED OUT connector. The connected loudspeaker systems have to be
designed for handling such high voltages. Please carefully read the power handling specications
as stated in the documentation of the according loudspeaker system and make sure to check
whether they are in compliance with the output capacity specications of the power amplier.
GROUND-LIFT SWITCH
The ground-lift switch allows eliminating noise loops. When operating the
power amplier in a 19“ rack-shelf system or cabinet together with other
equipment, setting the switch to its GROUNDED position is recommended.
When operating the power amplier together with appliances with differing
ground potentials, set the switch to its UNGROUNDED position
MAINS INPUT
Under normal circumstances, the mains fuse only blows in case of fault.
Replacing the fuse is only permissible for authorized service personnel
using a new fuse of the same type with identical amperage, voltage and
blow characteristics. The high-performance mains cord supplied with your
power amplier complies with applicable safety regulations, plus that its diameter corresponds to the
power amp’s power output capacity. Whenever possible make sure to use the supplied mains cord for
connecting the power amp to the mains network. Using a different mains cord with a smaller diameter
results in higher leakage, consequently reducing the amplier’s maximum power output capacity.
A plastic cover to prevent inadvertent erroneous connection protects the BRIDGED OUT connector.
Remove the cover only when actually operating the power amplier in Bridged-Mode.
WARNING:
The speaker output terminals are marked with a symbol “ ”, which signies that these
terminals present a shock hazard to the user.