Dynaudio SUB 250 COMPACT Speaker User Manual


 
Before operation
6 Dynaudio Sub 250
Controls and connections
POWER ON/OFF
Main power switch (to switch the subwoofer manually on and off).
LED: shows operation mode:
red = subwoofer switched on and in mute mode
green = subwoofer is activated
AC IN
Main power input.
GAIN
Subwoofer volume level.
SUB Lowpass
Subwoofer lowpass frequency: continuously variable from 50 to 150 Hz.
PHASE
Phase setting: phase can be set to 0° or 180°.
MODE
Subwoofer operation mode LFE or Slave.
LFE: setting if just one subwoofer is used or for first subwoofer if system
consists of multiple subwoofers. Note that the SUB Lowpass control does
not have an effect when the LFE Mode is selected.
Slave: setting for second and all following subwoofers. Note that the SUB
Lowpass, PHASE and GAIN controls do not have an effect when the Slave
Mode is selected.
SUB I/O
LFE/Slave in: input for LFE signal from processor/receiver. Note that the
signal must be a true LFE signal or already have been filtered by the
processor/receiver, as SUB Lowpass does not have an effect in combination
with the LFE input.
LFE/to Slave: output to next subwoofer if installed.
SAT/SUB Input
Input for full bandwidth signal from processor/receiver. This signal will be
processed according to the SAT Highpass setting and provided at the
SAT Output connection for satellite speakers to be connected.
SAT Output
Output for satellite speakers to be connected. This signal is processed according
to the SAT Highpass setting.
SAT Highpass
Allows cutting off low frequencies of the signal provided at the SAT Output.
Flat: signal is not processed
60: cut-off frequency at 60 Hz
80: cut-off frequency at 80 Hz