9
Troubleshooting
Problem Cause Action
Yellow wire not connected or incorrect voltage
Red wire not connected or incorrect voltage
Checkconnectionsforpropervoltage
(11~16VDC)
Blackwirenotconnected Checkconnectiontoground
Fuse blown Replace fuse
Speakerwiresnotconnected Checkconnectionsatspeakers
Oneormorespeakerwirestouchingeach
other or touching chassis ground
Insulateallbarespeakerwiresfrom
each other and chassis ground
Yellow or red wire touching chassis ground Checkforpinchedwire
Speakerwirestouchingchassisground Checkforpinchedwire
Incorrect fuse rating Use fuse with correct rating
Unitisnotmountedcorrectlyorbackstrapis
not secure
CD mechanism position out of alignment
CD transit screws still in place
Checkmountingsleeveandbackstrap
support
Physicaldefectinmedia(CD,CD-RorCD-
RW) Checkmediaforscratches
PressEJECTfor3secondstoreset
CD mechanism position
Remove 2 transit screws located on top
of the unit.
Unit will not turn on
(nopower)
Unit has power
(butnosound)
Unit blows fuses
Excessiveskipping
Unit will not accept
a disc
Error Codes
Error Code Cause Action
ER-1appearsondisplay Disc error PressejectorRESET
ER-2 appears on display Mechanism error PressejectorRESET
ER-3 appears on display Servo error or disc is in upside down PressejectorRESET
XD1222 OPERATION