Crown Audio 402and 602 Stereo Amplifier User Manual


 
XLS Series Power Amplifiers
page 17
Operation Manual
6 Specifications
Minimum Guaranteed Power XLS 202 XLS 402 XLS 602
120 VAC, 60 Hz Units, per channel, both channels driven
1 kHz with 0.5% THD
Stereo, 2 ohms (per ch.)
Stereo, 4 ohms (per ch.)
Stereo, 8 ohms (per ch.)
Bridge-Mono, 8 ohms
Bridge-Mono, 4 ohms
250W
200W
145W
400W
500W
570W
400W
260W
800W
1,140W
840W
600W
370W
1,200W
1,680W
240 VAC, 50 Hz Units, per channel, both channels driven
1 kHz with 0.5% THD
Stereo, 2 ohms (per ch.)
Stereo, 4 ohms (per ch.)
Bridge-Mono, 4 ohms
250W
225W
500W
610W
445W
1,120W
880W
670W
1,760W
Performance XLS 202 XLS 402 XLS 602
Sensitivity (volts RMS) for full rated power at 4 ohms 0.725 1.025 1.26
Frequency Response (at 1 watt, 22Hz - 20 kHz) ± 0.75 dB ± 0.75 dB ± 0.75 dB
Phase Response (at 1 watt, 10 Hz, 20 kHz) –10°, +19° –10°, +19° –10°, +19°
Signal to Noise Ratio below rated power (20 Hz to 20 kHz)
A-weighted, below rated power
No weighting, below rated power
> 100 dB
> 95 dB
> 100 dB
> 95 dB
> 100 dB
> 95 dB
Total Harmonic Distortion (THD) at 1 full bandwidth power, from 20 Hz to 1 kHz < 0.5% < 0.5% < 0.5%
Intermodulation Distortion (IMD) 60 Hz and 7 kHz at 4:1,
from full rated output to –40 dB
< 0.3% < 0.3% < 0.3%