Channel Plus MDS-6 Stereo Amplifier User Manual


 
Page 3
IR Emitter Modulation Frequency - these are
factory set to give optimum preformance of the
emitters. Factory setting is 40KHz.
Range is 32 KHz full CCW to 65 KHz full CW.
Doorbell Level - adjust to onboard
doorbell chime to appropriate level.
Factory setting -10db
Page Level - adjust to set page level to appropriate
level. Factory setting is -10db.
Page Sensitivity - set to match
page source output for VOX
function. Factory setting -20db.
INDIVIDUAL ZONE PC BOARDS
Switch - mutes sources when
doorbell or page is engaged.
Factory setting is on. Set to off
if you dont wish to have sources
muted when doorbell or page is
activated (such as a nursery, etc.).
Audio - disables doorbell and
page audio. Factory setting is
on.
If you want one zone to not be interrupted by paging or the dorrbell, set both switches to off.
If you wish to have one zone muted without the doorbell or paging audio set audio switch to off.
If you want to leave the source audio in place and have the page and doorbell audio superimposed over
the top of it, set switch to off.
DOORBELL/PAGING PC BOARD
IR OUTPUT PC BOARD (Fig. #1)
( This page is for information only - Consult your Installer for Application )
(Fig. #2)
(Fig. #3)
VR1
IR FREQ
502
502
502
502