Specifications:
Tecton 14.2 Tecton 22.2 Tecton 28.2 Tecton 24.4 Tecton 32.4 Tecton 38.4
Stereo
1)
8 Ω 226 W 355 W 517 W 698 W 918 W
1136 W
4 Ω 420 W 660 W 920 W 1216 W 1595 W 1900 W
2 Ω 730 W 1140 W 1420 W 1600 W
2)
1600 W
2)
1500 W
2)
Mono
16 Ω
3)
452 W 710 W 1034 W 1396 W 1836 W
2272 W
8 Ω
3)
840 W 1320 W 1840 W 2432 W 3190 W 3800 W
4 Ω
3)
1460 W 2280 W 2840 W 3200 W
2)
3200 W
2)
3000 W
2)
2 Ω
4)
840 W 1320 W 1840 W 2432 W 3190 W 3800 W
1 Ω
4)
1460 W 2280 W 2840 W 3200 W
2)
3200 W
2)
3000 W
2)
Output Circuitry
AB
2-Step
Class H
Frequency Response
20 Hz - 20 kHz, ± 0,2 dB / 8 Hz-50 kHz, +0, -3 dB
Input Impedance
14 kΩ balanced
Input Gain
selectable: 26 dB, 32 dB, or 1,4 V input sensitivity
Protection Circuits
incrush-current limitation, protection circuits against power- on/off transients, temperature monitoring, output DC
protection, temperature dependent power transistor SOA protection, intelligent mains fuse protection
Limiter
3 step switchable peak-limiter
Fan
Temperature dependent speed-controlled axial fan
Ground-Lift
input ground-lift switch on back panel
Indicators
LED’s for Mode, Signal, Clip, Output Current, Remote Control
Input Connectors
3-pin XLR, male and female per channel, pin 2 = in phase
Output Connectors
One 4-pole SPEAKON connector for each output channel (bi-amping possible)
Modes Of Operation
STEREO, BRIDGE MONO and PARALLEL-MONO
Options
Extended User Interface / E.U.I. — modules for i.e. Remote Control, Audio Network, Controller-DSP
Signal To Noise-Ratio
20 Hz - 20 kHz, 8 Ω load
> 107 dB (unweighted)
> 110 dB (A-weighted)
THD+N (typical)
20 Hz-20 kHz, 8 Ω load
10 dB below rated power
< 0,01 %
SMPTE (typical)
20 Hz-20 kHz, 8 Ω load
10 dB below rated power
< 0,01 %
Damping Factor
> 400
Net Weight
9,4 kg / 20,7 lbs
Shipping Weight
11 kg / 24,3 lbs
Dimensions (W x H x D)
483 x 88,9 x 330,7 mm / 19 x 3,5 x 13,0 inches (19”, 2U)
Shipping Dim. (W x H x D)
540 x 135 x 540 mm (0,04 m
3
) / 21,3 x 5,3 x 21,3 inches
1) All channels driven, 1 kHz, 1% THD @ 230 VAC 2) Peak Power, component tolerance dependent 3) Mono bridged 4) Parallel mono
All specification subject to change without notice
Ground lift
Mode of operation
(Stereo, Mono, Parallel mono)
Gain Setting
(26 dB, 32 dB, 1,4 V)
High pass filter ch. B
(Off, 30 Hz, 50 Hz)
High pass filter ch. A
(Off, 30 Hz, 50 Hz)
Clip limiter
(Off, Slow, Fast)
Channel B input
Channel A & B output
Channel A input
Channel B link