Cambridge Audio TT50 Turntable User Manual


 
11
T T50
The platter doesn't turn although the unit is switched on
The unit is not connected to the power supply unit.
No mains at the socket.
Drive belt is not fitted or has slipped off.
No signal through one or other channel or both
channels
Possible Wiring fault. Check that there are connections from the
cartridge to the internal tonearm wiring, and the turntable output to
your phono stage/amplifier.
Phono input not selected at amplifier.
Phono stage not switched on.
Amplifier not switched on.
Amplifier or speakers defective or muted.
No connection to the loudspeakers.
Strong hum on phono input
No earth connection from turntable to amplifier.
Turntable or Phono stage placed too close to transformers or other
generators of magnetic fields.
Distorted or inconsistent sound from one or both
channels
Record player is connected to wrong input of amplifier.
MM/MC switch on amplifier incorrectly set.
Stylus/needle or cantilever damaged.
Wrong rpm used for record.
Drive belt overstretched or dirty.
Platter bearing without oil.
Bad connections, plugs not fully pushed home.
Tracking force and/or anti-skate incorrectly adjusted.
Troubleshooting
For more frequently asked questions (FAQs), technical advice and
information on getting the most out of your TT50, please visit the
Support section on Cambridge Audio’s website:
www.cambridgeaudio.com/support.php
Turntable
Nominal speeds 33 1/3 or 45rpm
Speed variance ±0,8 %
Wow and flutter ±0,12 %
Signal to noise ratio <-65dB
Downforce range 1.0 to 3.0g (10 - 30mN)
Effective tonearm length 218.5mm (8.6")
Overhang 18.5mm
Outboard power supply 16V AC @ 500mA.
EU, UK and Canadian/US versions available
Power consumption 2W
Dimensions (W x H x D) 415 x 118 x 320mm, lid open
415 x 365 x 405mm, lid closed
Weight 5.5kg approx. unpacked
Tonearm mount Standard ½“
Cartridge (supplied)
Model Audio Technica AT95E
Type Moving Magnet
Stylus 0.4 x 0.7 mil elliptical diamond on
aluminium tube cantilever
(replacement part ATN95E)
Lifespan 1000-1500 hours
Recommended load resistance 47kohms
Recommended load capacitance 100 -220 pF total (inc. arm lead)
Frequency response 20Hz - 20kHz +/- 3dB
Channel separation > 22dB @1kHz
Channel balance < 2dB
VTA 20 degrees
Tracking force range 1.5 to 2.5g (15mN - 25mN)
Recommended tracking force 2.0g (20mN)
Nominal output voltage 3.5mV (@ 1kHz, 5cm/sec)
Mass 5.7g
Technical specifications
ENGLISH
Cartridge alignment protractor
AB
63mm
120mm
Measurement reference - mm
Cut the dotted line
using a scalpel or
similar
Measurement reference - mm
Cut the dotted line
using a scalpel or
similar
Cartridge alignment protractor
63mm
120mm
The cartridge protractor can also be photocopied or downloaded from
our website and printed. After copying/printing always check the mm
measurement reference scale against a ruler which then makes sure
your protractor is accurate. Copiers and printers can sometimes slightly
distort the images they print, so if you find this to be the case make
adjustments to the copier or print scaling and reprint until the scale is
correct.