Bosch Diagnostics 1 689 989 001 2007-05-30|
Maintenance | KTS 200 | 25 | 25
6. Maintenance
6.1 Cleaning
The housing and the display on the KTS 200 may only
be cleaned with soft cloths and with neutral cleaning
agents. Do not use any abrasive cleaning agent or rough
cleaning cloths.
6.2 Spare and wearing parts
Description Order number
System tester KTS 200 (green) 1 687 023 279
System tester KTS 200 (blue) 1 687 023 428
System tester KTS 200 (gray) 1 687 023 429
Power pack
Power supply lead
(<)
1 687 023 889
1 684 461 106
USB connecting lead, 1 m
(<)
1 684 465 491
OBD diagnostic lead, 1.5 m
(<)
1 684 465 555
Wall bracket 1 681 320 082
(<)
Wearing parts
7. Technical data
7.1 General data
Property Value/Range
Operating voltage 7 VDC — 34 VDC
Power consumption approx. 7 Watt
LCD display 3,5"
320 * 240 Pixel
Dimensions (L x W x H) 140 x 220 x 40 mm
Weight (without connecting leads) 600 g
Operating temperature 5 °C – 40 °C
Relative humidity 90 % (at 25 °C)
Protection class IP 30
7.2 Interface protocols
The following interfaces and their associated protocols
are supported for control unit diagnosis in compliance
with ISO 15031:
ISO 9141-2 (communication lines K and L)
SAE J1850VPW und SAE J1850PWM
(communication lines BUS+ and BUS-)
CAN ISO 11898 ISO 15765-4 (OBD)
(communication lines CAN-H and CAN-L)
CAN Single Wire
CAN Low Speed
7.3 Power pack
Property Value/Range
Input voltage 90 VAC — 264 VAC
Input frequency 47 Hz — 63 Hz
Output voltage 15 V
Operating temperature 0 °C — 40 °C
R
R
R
R
R
en