Belkin AP30800fc10-BLK Home Theater System User Manual


 
Installation
Note:
Before installation, please inspect the Belkin PureAV Battery Backup upon
receipt to make sure it is not damaged.
Connect To AC Utility Power
Connect the AC inlet to utility power via the power cord. Check whether
the “Site Wiring Fault” indicator is lit or not. If so, please check the
utility wiring.
Charging The Battery
For best results, charge the battery for eight hours prior to initial use. The
Belkin PureAV Battery Backup charges its battery whenever it is connected
to the utility power.
Plug In Power Devices
Plug your devices into the AC outlets on the rear of the Belkin PureAV
Battery Backup. To use the Belkin PureAV Battery Backup as a master
on/off switch, make sure all of the loads are switched on.
Caution: never connect a laser printer or scanner to the
battery-backup outlets of the Belkin PureAV Battery Backup. A laser
printer or scanner draws significantly more power when in use than
when idle. This may overload the Belkin PureAV Battery Backup.
Turning On the Belkin PureAV Battery Backup
Turn on your Belkin PureAV Battery Backup by pressing and holding the
“On/Off/Test” button for approximately two seconds until the green “ON
LINE” light comes on.
Turning Off the Belkin PureAV Battery Backup
Turn off the Belkin PureAV Battery Backup by pressing and holding the
“On/Off/Test” button for more than two seconds until the “ON LINE” or
“ON BATTERY” light goes off.
To Conduct a Self-test
Use the self-test to verify both the operation of the Belkin PureAV Battery
Backup and the condition of the battery. In normal utility power, push the
“On/Off/Test” button less than 1.5 seconds and the Belkin PureAV Battery
Backup performs a self-test function. During the self-test, the Belkin PureAV
Battery Backup operates in backup mode.
Note: During the self-test, the Belkin PureAV Battery Backup briefly
operates on battery-backup power (the “ON BATTERY” LED comes on).
If the Belkin PureAV Battery Backup passes the self-test, it returns to
online operation. If the Belkin PureAV Battery Backup fails the self-test,
it immediately returns to online operation and lights the “REPLACE
BATTERY” LED. The loads are not affected. Recharge the battery
overnight and perform the self-test again. If the “REPLACE BATTERY”
LED is still on, the battery will need to be replaced. Please contact
Belkin Customer Service for assistance.
Product Features
Belkin PureAV Battery Backup
6