Belkin AP30800fc10-BLK Home Theater System User Manual


 
Belkin PureAV Battery Backup
3
Belkin PureAV Battery Backup Features
and Functions
Indicator Condition Meaning
BATTERY ON
(Green LED)
Solid
Green
The Belkin PureAV Battery Backup is on
battery-backup mode and an intermittent
audible alarm is on. The Battery Backup will
begin shutdown procedure.
Flashing
Green
Battery is low. The Belkin PureAV Battery
Backup will start shutdown. The buzzer sounds
an audible alarm.
OVERLOAD
(Yellow LED)
Solid
Yellow
The Belkin PureAV Battery Backup shut down
due to an overload or short-circuit condition.
Flashing
Yellow
Battery output is drawing more power than the
Battery Backup can provide.
REPLACE
BATTERY
(Red LED)
Solid
Red
Battery is weak or bad; the battery needs
to be replaced.
SITE WIRING
FAULT
(Red LED)
Solid
Red
There is either no ground circuit or a
reversed polarity in the building wiring.
LOAD
(Yellow LED) Solid
Yellow
This display shows the Belkin PureAV Battery
Backup output load percentage level of 17%,
33%, 50%, 67%, and 85%.
BATTERY
(Green LED) Solid
Green
This display shows the battery capacity
percentage level of 20%, 40%, 60%, 80%, and
100%.
On/Off/Test Switch
LED Indicator
Site Wiring Fault
Battery On
Battery
Load
Replace Battery
Overload