Behringer ULTRAWAVE B300 Speaker User Manual


 
7
ULTRAWAVE B300
1.3 Control elements
Fig. 1.1: Rear panel control and connecting elements of the ULTRAWAVE
1
The OVL LED (= overload) lights up as soon as any one of the built-in protections has been activated.
For improved control a second overload LED is installed on the front panel of the speaker cabinet.
2
The LINE LED lights up when the input sensitivity of the B300 has been set to LINE level with switch
. When you have a mixing console or any other playback device (e.g. CD player) connected,
be sure to set this switch always to LINE level!
3
The VOLUME control governs the overall volume level of your ULTRAWAVE.
4
The INPUT switch changes the input sensitivity from line to microphone level, and vice versa.
5
The MIC LED lights up when the input sensitivity of the B300 is set to microphone level.
6
Use the HI control to adjust the high-frequency range of the built-in equalizer.
7
Use the LO control to adjust the low-frequency range of the built-in equalizer.
8
This stereo 1/4" TRS connector is the input for the signal source. You can also connect a microphone
(in this case, switch must be set to MIC!)
9
This XLR connector is a balanced input for the signal source. You can also connect a microphone (in
this case, switch must be set to MIC!)
10
The LINK OUTPUT is directly connected to the inputs of the B300 and provides a one-to-one copy of the
input signal, for example, to loop the signal through to the input of another device (e.g. a second B300).
11
Use the POWER switch to put the ULTRAWAVE into operation.
12
FUSE HOLDER/VOLTAGE SELECTOR and MAINS CONNECTOR. Please make sure that your local
voltage matches the voltage indicated on the unit, before you attempt to connect and operate the
ULTRAWAVE. Blown fuses may only be replaced by fuses of the same type and rating. Some models
allow for inserting the fuse holder in two different positions, in order to switch over from 230-V to 115-V
operation, and vice versa (see chapter 1.2.1). Please note that for 115-V operation outside Europe, you
need a fuse of a higher rating.
+ The serial number of your ULTRAWAVE is printed on the rear panel. Please take the time to fill
out and return the warranty card within 14 days after the date of purchase, so as to be entitled
to benefit from our extended warranty. Or use our online registration option available on the
Internet at www.behringer.com.