8
18. Ground lift switch
This switch is used to disconnect the signal ground from the mains and chassis earth. If it is determined
that the equalizer is the cause of hum or buzz in your system due to a ground loop, move this switch to the
"lift" position.
4. INSTALLATION & CONNECTION
4.1 Mains Connection
Please ensure that the EQU Series Graphic Equalizer is set to the correct supply voltage before plugging
the power cord into the wall outlet , use the same fuse as marked on the fuse holder at the AC power
connection socket.
The mains connection of the is made by using the enclosed mains cable and
a standard IEC receptacle. It meets all of the international safety certification requirements.
EQU Series Graphic Equalizer
4.2 Audio Connection
The presents with balanced XLR & 1/4" TRS and unbalanced RCA connectors,EQU Series Graphic Equalizer
and it can be interfaced by several ways to support a variety of applications without any signal loss. The
EQU Series Graphic Equalizer can be used on a single instrument by connecting to a mixing console's main
inserts, or on an entire mix "in-line" between a mixing console's outputs and a power amplifier.
- Wiring Configuration
Either the 1/4" TRS phone jack or the XLR connector can be wired in balanced and unbalanced modes, which
will be determined by the actual application status, please wire your system as the following wiring examples:
19. Fuse holder / Voltage selector
This is a dual voltage unit. Before you attempt to connect and operate the unit, please make sure that your
local voltage matches the voltage on the fuse-holder cover.
Caution: The fuse protecting the AC supplies circuits of this unit. The fuse can only be changed by
a qualified technician, in the event of a fault or changing the supply voltage. If the fuse continues to
blow after replacing, discontinue use of this unit before repaired.
The fuse-holder above the AC connector on the rear of the chassis has 3 triangular markers(please
refer to the above pictures), with two of these triangles opposing each other, your unit is set to the
operating voltage printed next to these markers.
To change, pull fuse-holder out and rotate 180,then push in again.
20. AC Inlet
This connector is meant for the connection of the supplied main cord.
Do not insert power cable into unit until voltage has been correctly set. Do not plug power cable into AC
power until voltage has been correctly set.
110-120V
220-240V
THISIS SETFOR
110V AC TO 120V
ACOPERATION
THISIS SETFOR
220VAC TO240V
ACOPERATION
220-240V
110-120V
1/4"TRS jack
Unbalanced Input
1/4"TRS jack
Balanced Input
XLR Balanced InputXLR Unbalanced Input
NOTE : While you can use any input connector with any output connector, only one set of these con-
nectors is to be used at one time, detail wiring and connection, please refer to 4.2 audio connection.