Aiphone AXW-AVR Stereo Receiver User Manual


 
AXW-AVR
Pg. 2
OFF ON
CEU
OUT IN
VIDEO
AXW-AVR
AUDIO
+ -
INOUT
+ -
RELAY
NO NO
OUT
+ -
CALL
+ -
IN
75 OHM
COMPATIBLE DOOR STATIONS (AXW-AVT):
AX-DV Surface mount, die cast zinc, vandal resistant, Audio-Video
AX-DVF Flush mount, stainless steel, vandal resistant, Audio-Video
AX-DM Mullion mount, black plastic, Audio Only
IF-DA Surface mount, brown plastic, Audio Only
IE-DC Surface mount, brown plastic w/aluminum, Audio Only
IE-JA Flush mount, 2 gang, stainless steel faceplate, Audio Only
IE-SS Flush mount, 2-gang, stainless steel, vandal resistant, Audio Only
IE-SSR Flush mount, 2-gang, stainless steel, vandal resistant w/red mushroom call button, Audio Only
AXW-AVR TERMINAL DEFINITIONS:
RELAY NO, NO: Normally Open relay contact, activated whenever communication is active.
CALL IN/OUT: Transistor-switched input / output to be connected to relay input / output on
transmission equipment. ‘Call In’ indicates call placed by door station, ‘Call Out’
indicates master-initiated activity (polarity of input / output indicated by ‘+’ and ‘-’).
AUDIO IN/OUT: Input / Output connections for audio transmission (line level, polarity indicated by
‘+’ and ‘-’).
VIDEO IN: Composite input signal from CCTV camera, if used in place of AX-series audio
video door station.
VIDEO OUT: Composite output to external transmission equipment. Source dependent upon
CCTV / DOOR switch.
OFF/ON SWITCH: Determines whether AX-series audio video door station video (‘DOOR’ setting) or
external CCTV video (‘CCTV’ setting) will be present on ‘VIDEO OUT’ for
connection to external transmission equipment.
CEU (RJ-45 Jack): RJ-45 connection from AXW-AVR to CEU, simulating a standard AX-series Audio/
Video door station.
PROGRAMMING:
1. Follow standard AX programming procedures as
described in the AX Installation & Operation
manual (included on CD with the AX CEU).
2. When configuring door stations, be sure to set the
station number corresponding to the AXW-AVT / -
AVR to “Video” in the AX setup utility.