TO INSTALL RANGE HOOD
For most efficient operation, top of hood should be
approximately 66 (167.6 CM) inches from floor.
1. Mark locations for electrical wiring from dimensions
grven in Figure 1.
2 Cut hole to accomodate electrical wiring. Be sure to
minimize openings through outside walls or the ceiling.
These will have to be sealed later.
3. Run wire through wall or cabinets according to
National Electrical Code and applrcable local codes. DO
NOT turn power on until installation is complete.
4. Remove screws holding junction box cover. See
Frgure 2.
5. Lrft the hood into position and mark the location of
each of the four keyhole mounting slots.
6 Remove the hood and start all four screws in the
center of the narrow neck of the keyhole slot marked on the
cabinet bottom.
7. Lift the hood into position srmultaneously feeding
the electrical wire through the knockout.
8. Tighten four mounting screws to secure hood to
cabrnet Be sure the screw heads are in the narrow neck of
the keyhole slot. See Figure 3.
9 Complete electrrcal wiring In the junction box
according to the National Electrical Code and applicable
local codes.
NOTE, Thus unit must be permanently grounded
10 Replace junction box cover. See Figure 2.
11 Seal holes around wiring passing through ceiling or
outside wall with caulking or lnsulatron to prevent energy
loss.
KEYHOLE SLOT
IN CANOPY
Figure 2
Figure 4
SCREW --
(IN INSTALLATION
PARTS BAG)
Figure 3
Page 2