VBCV Professional
Custom Wall
Ventilator System
VICV Professional
Custom Island
Ventilator System
DBCV Designer
Custom Wall
Ventilator System
DICV Designer
Custom Island
Ventilator System
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM • 1-888-VIKING1
VENTILATION
Built-In Custom Ventilator Systems
Proper installation/ducting is extremely
important to ensure maximum
performance. Use a qualified and
trained installer.
DUCTING
• Check with a qualified and
trained installer or local codes
for makeup air requirements, if
any.
• Max. duct run length
o For 300 – 1,200 CFM—
50’ (152.4 m)
o
For 1,500 CFM—75’ (22.9 m)
o Duct run length is for
general reference only;
always use a qualified and
trained installer.
o Straight runs and gradual
turns are best; for example,
each 90° elbow is equivalent
to 5’ – 10’ (1.52 – 3.05 cm)
of straight run.
• 7” (17.8 cm) round duct for
300 – 600 CFM; 10” for 900 –
1500 CFM
o Never use flexible duct; it
creates back pressure/air
turbulence and greatly
reduces performance.
GAS
Not applicable
ELECTRICAL
• Hardwire direct with two-wire
ground
• 120 VAC/60 Hz
• Max. amp usage (rating
includes recommended
ventilator kit rating)—see
Installation Requirements
table
PLUMBING
Not applicable
Installation Requirements
*1200 CFM interior and exterior (if applicable) ventilator should be used with all outdoor approved models and when indoor models are installed over
ranges/rangetops with gas grill.
**Must use 8” duct from canopy to ceiling – transition to 10” duct past duct cover.
Note: Exhaust capacity based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be
greatly overstated.
UTILITY REQUIREMENTS
RELEASED 8/18/08
©2008 VRC—INFORMATION SUBJECT TO CHANGE
Model Ventilator Kits
Interior Exterior
Duct Size
Interior Exterior/In-Line
Max. Amps
Interior Exterior
VBCV3038 VIV300/600/1200* VEV900/1200*
VIL900/1200*
7” (17.8 cm)/
10” (25.4 cm)
10” (25.4 cm) 5.0/6.2/8.7 8.7/6.1/3.0/4.8
VBCV3638 VIV300/600/1200* VEV900/1200*
VIL900/1200*
7” (17.8 cm)/
VIL900/1200*
10” (25.4 cm) 5.0/6.2/8.7 8.7/6.1/3.0/4.8
VBCV4238 VIV600/1200* VEV900/1200*
VIL900/1200*
7” (17.8 cm)/
VIL900/1200*
10” (25.4 cm) 6.2/8.7 8.7/6.1/3.0/4.8
VBCV4838 VIV1200* VEV1200*/1500/VIL1200* 10” (25.4 cm) 10” (25.4 cm) 11.1 8.4/9.1/4.8
VBCV5438 VIV1200* VEV1200*/1500/VIL1200* 10” (25.4 cm) 10” (25.4 cm) 11.1 8.4/9.1/4.8
VBCV6038 VIV1200* VEV1200*/1500/VIL1200* 10” (25.4 cm) 10” (25.4 cm) 11.5 8.8/9.5/4.8
VBCV6638 VIV1200* VEV1200*/1500/VIL1200* 10” (25.4 cm) 10” (25.4 cm) 11.5 8.8/9.5/4.8
VICV3698 VIV600/VIV1200* VEV900/1200*/VIL900/VIL1200* 7” (17.8 cm) 10” (25.4 cm) 4.9/7.4 7.4/4.7/3.0/4.8
VICV4298 VIV600/1200*
VEV900/1200*/1500/
VIL900/VIL1200*
7” (17.8 cm) 10” (25.4 cm) 4.9 7.4/4.8/5.4/3.0/4.8
VICV5498 VIV1200* VEV1200*/1500/VIL1200 10”(25.4 cm) 10” (25.4 cm) 8.2 5.6/6.2/4.8
VICV6698 VIV1200* VEV1200*/1500/VIL1200 10”(25.4 cm) 10” (25.4 cm) 9.0 6.3/7.1/4.8
DBCV3082 DIV300/440 DEV900**/1200*/DIL900/DIL1200 7” (17.8 cm) 10” (25.4 cm) 1.7/3.2 6.6/3.9/3.0/4.8
DBCV3682 DIV300/440 DEV900**/1200*/DIL900/DIL1200 7” (17.8 cm) 10” (25.4 cm) 1.7/3.2 6.6/3.9/3.0/4.8
DBCV4282 DIV440 DEV900**/1200*/DIL900/DIL1200 7” (17.8 cm) 10” (25.4 cm) 3.2 6.6/3.9/3.0/4.8
DBCV4882 DIV880 DEV1200/1500/DIL1200* 10” (25.4 cm) 10” (25.4 cm) 5.6 4.3/5.1/4.8
DICV3632
DIV440 DEV900**/1200*
DIL900/DIL1200
7” (17.8 cm) 10” (25.4 cm) 4.0 7.5/5.2/3.0/4.8
DICV4232
DIV440 DEV900**/1200/1500
DIL900/DIL1200
7” (17.8 cm) 10” (25.4 cm) 4.0 7.5/5.2/6.0/3.0/4.8
DICV5432 DIV880 DEV1200/1500/DIL1200 10” (25.4 cm) 10” (25.4 cm) 6.4 5.2/6.0/4.8