dia. duct location
dia. duct location
For 900, 1200 or 1500 CFM Exterior
or In-Line Ventilator Installation
For 300, 600 or 1200 CFM Interior
Ventilator Installation
900 or 1200 CFM Exterior
or In-Line Ventilator Installation
36”, 42” W. Models
300 or 600 CFM Interior
Ventilator Installation
36”, 42” W. Models
D
36” W. 17-1/8” (43.5 cm)
42” W. 20-1/8” (51.1 cm)
48” W. 23-1/8” (58.7 cm)
60” W. 29-1/8” (74.0 cm)
(VBCV Wall Custom Ventilator System)
Built-In Wall Custom Ventilator
System Dimensions
(VBCV Models)
Clearance Dimensions
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-
grill. Max duct run is 50 ft (15.2 m).
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m).
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
VBCV Wall Custom Ventilator System
Description 36” 42” 48” 60”
Number of filters
2 2 3 4
Heat lamps
1 1 2 3
Interior ventilator kits
VINV300/
600/1200*
VINV600/
1200*
VINV1200* VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL1200 DIL900/1200 DIL1200 DIL1200
Interior duct size
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
Exterior duct size
10” (25.4
Interior—Maximum amps
4.2/5.2 10.8 10.8 10.8
Exterior—Maximum amps
8.0/5.3 8.0/5.3 7.8/8.5 7.8/8.5
In-Line—Maximum amps
5.3/7.2 5.3/7.2 9.6 10.0