![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/a/71/a716f2be-e995-4ea9-8e14-7fb4035c5a2c/a716f2be-e995-4ea9-8e14-7fb4035c5a2c-bg8.png)
TriggerLinc Owner’s Manual
Using TriggerLinc’s Multi-Scene Mode
In Multi-Scene Mode, TriggerLinc will:
• Activate Scene 1 when it opens
• Activate Scene 2 when it closes
This mode is ideal when you need more flexibility:
• For rooms where you want the lights left on after the door is closed – simply don’t Link any
Responders to Scene 2 in this case
• Turning lights on at full-bright when a door is opened and dim when the door is closed
• Activating two independent scenes when a door/window is opened as opposed to closed
Linking in Multi-Scene Mode
1) Open the TriggerLinc cover and ensure the jumper is uninstalled (or removed). When uninstalling the
jumper, the battery will need to be removed and then reinstalled for the new jumper setting to take
effect
2) Move the TriggerLinc magnet away from the main case, putting it in the open state
If TriggerLinc was closed, its Status LED
will flash once
3) Link the desired Responders for when TriggerLinc opens (Scene 1). See Linking TriggerLinc to an
INSTEON Responder.
Scene 1
will activate whenever TriggerLinc is opened and will toggle on and off when the Set
button is tapped (while TriggerLinc is opened)
4) Move the TriggerLinc magnet close to the main case, putting it in the closed state
The TriggerLinc Status LED
will flash once
5) Link the desired Responders for when TriggerLinc opens (Scene 2)
Scene 2
will activate whenever TriggerLinc is closed and will toggle on and off when the Set
button is tapped (while TriggerLinc is closed)
6) Test that the Responders are working as expected by opening and closing your door or window
Scene 1
will activate when the door or window is opened and Scene 2 will activate when closed
Unlinking in Multi-Scene Mode
1) Open the TriggerLinc cover and ensure the jumper is uninstalled (or removed)
2) Move the TriggerLinc magnet away from the main case, putting it in the open state
If TriggerLinc was closed, its Status LED
will flash once
3) Unlink the desired Responders from Scene 1. See Unlinking an INSTEON Responder from
TriggerLinc.
The Responders
will no longer respond when TriggerLinc is opened or the Set button is tapped
4) Move the TriggerLinc magnet close to the main case, putting it in the closed state
The TriggerLinc Status LED
will flash once
5) Unlink the desired Responders from Scene 2
The Responders
will no longer respond when TriggerLinc is closed or the Set button is tapped
6) Test by opening and closing your door or window
The Responders
will no longer respond when TriggerLinc is opened or closed
Page 8 of 12