Display Setup
Display setup allows you to program how labels are displayed on the monitor. The following
labels are available:
PRESET LABEL Identifies preset.
ZONE LABEL Identifies zone.
ZOOM Identifies the amount of magnification.
AZIMUTH
1
/ELEVATION
2
Amount of pan from 0° and the amount of tilt from 0° horizontal.
DIRECTION Displays compass direction.
ALARM MESSAGE Displays activated alarm.
DATE/TIME Displays current date and time.
A preset label is displayed when a preset is called. A zone label is displayed when the system
moves into a zone. The zoom ratio label is displayed when zoom is activated. Azimuth/elevation
and direction labels are displayed when pan/tilt is activated. An alarm message appears on the
monitor when an alarm occurs.
The following settings are available for each label except date and time:
OFF Label is not displayed when activated.
CONSTANT The label is continually displayed when activated.
2 SECONDS The label is displayed for 2 seconds after activation.
5 SECONDS The label is displayed for 5 seconds after activation.
10 SECONDS The label is displayed for 10 seconds after activation.
The settings for date and time are ON or OFF.
1
Azimuth is the pan angle from 0° to 359°.
2
Elevation is the tilt position from 0° (horizon) to -90°.
*This setting applies only to Pressurized Spectra IV dome systems.
EXIT
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
BACK
EXIT
PRESET LABEL
ZONE LABEL
ZOOM
AZIMUTH/ELEVATION
DIRECTION
ALARM MESSAGE
DATE/TIME
<LABEL POSITIONS>
RESTORE FACTORY DEFAULTS