6-4. Stainless Steel And 100% CO2 Weld Parameters
Select Wire Type, Polarity, and Shielding
Material Thickness
Select Wire Type, Polarity, and Shielding
Gas
re
ze
20 ga 18 ga 16 ga 14 ga 1/8 in. 3/16 in. 1/4 in. 5/16 in.
Shop Settings (Wall or Premise Power, 230 V 1 Ph)
Solid ER70S−6 (DCEP)
0.024 3.2/25 3.5/25 4.0/40 4.5/50 5.0/60 7.0/85 −−− −−−
100% CO2 Shielding Gas
0.030 3.0/15 3.5/20 4.0/25 4.5/35 5.5/45 6.0/55 6.5/65 10.0/75
0.035 −−− 3.0/12 4.0/20 4.5/30 5.5/35 6.0/40 6.5/50 10.0/55
Stainless Steel (DCEP)
0.024 3.5/30 3.5/45 4.0/50 4.5/70 5.0/80 6.0/95 −−− −−−
Tri−Mix Shielding Gas
90% HE/7.5% Ar/ 2.5% CO2
0.030 3.5/25 3.5/30 4.0/45 5.0/60 5.0/70 6.0/85 7.5/95 −−−
.
.
0.035 −−− 2.5/20 3.5/25 4.0/40 4.5/50 6.0/65 7.5/80 −−−
Aluminum 4043 (DCEP)
0.030 2.0/70 2.0/70 4.0/70 5.0/70 8.0/95 10/100
100% Argon Shielding Gas
0.035 2.5/65 4.0/60 5.0/65 8.0/90 10/90
Field Setting (Generator Power)
Solid ER70S−6 (DCEP)
0.024 3.5/25 3.5/25 4.0/40 4.5/50 5.0/60 10.0/70 −−− −−−
100% CO2 Shielding Gas
0.030 3.0/15 3.5/20 4.0/25 5.0/35 6.0/45 10.0/55 10.0/65 −−−
0.035 −−− 3.0/12 4.0/20 10.0/30 10.0/35 −−− −−− −−−
Stainless Steel (DCEP)
0.024 3.5/30 3.5/45 4.0/50 5.5/70 10.0/80 10.0/95 −−− −−−
Tri−Mix Shielding Gas
90% HE/7.5% Ar/ 2.5% CO2
0.030 4.5/25 4.5/30 6.0/45 10.0/60 10.0/70 10.0/85 −−− −−−
.
.
0.035 −−− 3.0/20 4.0/25 6.0/40 10.0/50 −−− −−− −−−
Aluminum 4043 (DCEP)
0.030 4.0/70 4.0/70 6.0/70 10/75
100% Argon Shielding Gas
0.035 4.5/60 6.0/60 10/65