A SERVICE OF

logo

OM-184 227 Page 7
SECTION 3 INSTALLATION
3-1. Specifications
Output
Frequency
Rated Output
Required
Reflective
Inductance
Amperes Input at
Rated Load Output 50
or 60 Hz, Three-Phase
Overall Dimensions Weight
Frequency
I
n
d
uc
t
ance
460 V KVA KW
10 To 50 kHz
25 kW At
100% Duty
Cycle Max
750 A (RMS),
700 V (RMS)
2.5 To 50 μh
39
0.29*
30.8 27.19
Length: 31 in
(787 mm)
Width: 16 in
(406 mm)
Height: 27 in
(686 mm)
165 lb
(75 kg)
*While idling
WARNING
HIGH-FREQUENCY RADIATION can interfere with radio navigation, safety services,
computers, and communications equipment.
Have only qualified person familiar with electronic equipment perform this installation.
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
If notified by the FCC about interference, stop using the equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut.
Ref. ST-801 826-C
Tools Needed:
3-2. Connecting Head/Coil to Power Source
1 Rear Panel
2 Connecting Block
. Do Not Exceed 58 in lb
(6.6 N
.
m) of torque when
making connections.
7/16 in
2
1