8 Placing the Battery Pack into the Charger
HX1 Multi-Charger User’s Guide E-EQ-HX1CHGROG-B-ARC
Battery Recalibration
LXE recommends recalibrating the HX1 battery packs once per month. The battery pack is an
intelligent design that keeps track of available capacity by monitoring the flow of the charge
within the battery. Since the analysis routine is conservative, under reporting of battery pack
capacity may occur. Over time, the results are cumulative. The more times a battery has been
charged, the greater the potential for under reporting.
Note: The HX1 Multi-Charger can display the number of charge cycles for the battery pack
since its last recalibration. Please see “Interpreting the LEDs and Displays”, later in
this chapter for more information.
How to: Recalibrate the HX1 Battery Pack
1. Insert the battery as described earlier in this section.
2. The LEDs for the charging pocket briefly illuminate yellow, red, green then the yellow. The
LED is illuminated solid yellow as the charging process begins.
3. Press and hold the Recalibrate button until the LED begins flashing yellow.
4. The display shows either ‘1c’ or ‘2c’ depending on the number of recalibration cycles the
Multii-Charger has determined necessary.
5. When the process is complete, the LED is illuminated green.