A-1
INSTALLATION
SP-125 PLUS
Fuse or
Output Mode Input Voltage Breaker Size Input Amps Extension Cord
RATED 115V/60Hz 20 Amp 20 Three Conductor
#14 AWG
(2.1 mm
2
) or Larger
for up to
MAXIMUM 115V/60Hz 25 Amp 25 25 feet (7.6m)
Three Conductor
#12 AWG
CSA 115V/60Hz 15 Amp 15 (3.3 mm
2
) or Larger
for up to
50 feet (15.2 m)
TECHNICAL SPECIFICATIONS – SP-125 Plus
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height Width Depth Weight
12.0 in 9.75 in 16.5 in 54 Ibs
305 mm 248 mm 419 mm 24.3 kg
PHYSICAL DIMENSIONS
Standard Voltage/Frequency Input Current
115V/60Hz 20 Amps - Rated Output
115V/60Hz 25 Amps - Maximum Output
115V/60Hz 15 Amps - CSA Rated output
Duty
Cycle Amps Volts at Rated Amperes
20% Duty Cycle – Rated DC Output 90 18
20% Duty Cycle - CSA Rated Output 63 20
Welding
Current Range (Continuous) Maximum Open Circuit Voltage Auxiliary Power
Rated DC Output: 0 - 90 amps 28 N/A
CSA Rated DC Output: 0 - 63 amps
Useable Amperage Range 25 – 125 Amps
.