A SERVICE OF

logo

3. DC Output Specification
3.1 Output Current / Loading
The following table defines power and current rating. The power supply shall meet both static and
dynamic voltage regulation requirements for minimum load condition.
Power Module Only:
Output
Voltage
+12V +5VSB
Max. Load 32A 2A
Min. Load 1A 0.1A
Total Output
384W 10W
Power Module with PDB(Power Distribution Board),
Output
Voltage
+5V +3.3V +12V -12V +5VSB
Max. Load 20A 20A 32A 0.5A 2A
Min. Load 0A 0A 1A 0A 0.1A
Total Output
400W
Table 2– Output Loads Range 1:
Note 1: Maximum continuous total DC output power should not exceed 400 W.
3.2 DC Voltage Regulation, Ripple and Noise
The power supply output voltages must stay within the following voltage limits when operating at
steady state and dynamic loading conditions. All outputs are measured with reference to the return
remote sense (ReturnS) signal. The +5V,+3.3V, +12V, -12V and +5VSB outputs are measure at the
power supply connectors references to ReturnS. The +5V and +3.3V is measured at its remote sense
signal (+5VS, +3.3VS) located at the signal connector.
Output Voltage +5V +3.3V +12V -12V +5VSB
Load Reg. +/-5% +/-5% +/-5% +/-5% +/-5%
Line Reg. ±1% ±1% ±1% ±1% ±1%
Ripple & Noise 50mv 50mV 120mV 120mV 50mV
Table 3 – Regulation, ripple and noise
Ripple and Noise shall be measured using the following methods: