A SERVICE OF

logo

Page 13 of 19 2452-222/2452-422/2452-522 - Rev: 1/21/2014 7:50 AM
X10 transmitter Yes
X10 receiver Yes
X10 status response Supported
X10 resume dim Supported (by setting local on-level to zero)
X10 minimum transmit level 3.2 Vpp into 5 Ohms
X10 minimum receive level 20mV into 5 Ohms
X10 messages repeated No
Mechanical
Mounting 35mm (top hat) DIN Rail
Wires NA
Max Cable Size 4mm2, 12 AWG (2.72mm Diameter)
Min Cable Size 1.5mm2, 15 AWG
Screw DIN Rail connections Line, Neutral, Load, Sense 1, Sense 2
Case color White
Set button Yes
Plastic UV stabilized polycarbonate
Beeper Yes
Beep on button press Optional (off by default)
LED 1, RGB
Dimensions 3.14"H x 2.05"W x 2.48"D (80mm x 52mm x 63mm)
Weight 6.17 oz (175g)
Operating environment Indoors
Operating temperature range 32° to 104° F (0° to 40° C)
Operating humidity range 0-90% relative humidity
Storage temperature range -4° o to 158° F (-20° to 70° C)
Electrical
Voltage 100VAC to 240VAC
RF Frequency
US 915 MHz
EU 869 MHz
AUS/NZ 921 MHz
Electrical Frequency 50/60Hz auto detected at power-up
Load type(s)
Resistive
Low voltage halogen
Incandescent
Maximum load
300 watts (@ 240VAC)
300 watts (@ 120VAC)
Minimum load 5 watts
User replaceable fuse
US 16A, 5x20mm slow blow/burn glass fuse
EU 2A, 5x20mm slow blow/burn glass fuse