5K320 SATA OEM Specification
114
State shall contain a value indicating the state of the device when the command was issued to the
device or the reset occurred as described below.
Value State
x0h Unknown
x1h Sleep
x2h Standby
x3h Active/Idle
x4h SMART Off-line or Self-test
x5h-xAh Reserved
xBh-xFh Vendor specific
Note: The value of x is vendor specific .
14.17.2.4 Device error count
This field shall contain the total number of errors attributable to the device that have been reported
by the device during the life of the device. This count shall not include errors attributed to the
receipt of faulty commands such as commands codes not implemented by the device or requests with
invalid parameters or invalid addresses. If the maximum value for this field is reached the count
shall remain at the maximum value when additional errors are encountered and logged.
14.17.3 Extended Self-test log sector
The following table defines the format of each of the sectors that comprise the Extended SMART
self-test log.
The Extended SMART self-test log sector shall support 48-bit and 28-bit addressing. All 28-bit
entries contained in the SMART self-test log, defined in “Self-test log data structure” shall also be
included in the Extended SMART self-test log with all 48-bit entries.
Description Bytes
Offset
Self-test log data structure revision number
1
00h
Reserved 1
01h
Self-test descriptor index (7:0) 1
02h
Self-test descriptor index (15:8) 1
03h
Descriptor entry 1 26
04h
Descriptor entry 2 26
1Eh
...
Descriptor entry 18 26
1D8h
Vendor specific 2
1F2h
Reserved 11
1F4h
Data structure checksum 1
1FFh
512
Table 79 Extended Self-test log data structure
These descriptor entries are view ed as a circular buffer. The nineteenth self-test shall create a
descriptor entry that replaces descriptor entry 1. The next self-test after that shall create a
descriptor entry that replaces descriptor entry 2, etc. All unused self-test descriptors shall be filled
with zeros
14.17.3.1 Self-test log data structure revision number
The value of this revision number shall be 01h.