A SERVICE OF

logo

If you get one of these messages during the upgrade, the rmware upgrade failed, but
the unit continues working with the existing rmware without an interruption in service.
The upgrade process checks for sufcient memory before activating the new rmware
image. The rmware upgrade does not complete without sufcient memory. Please
contact HP Customer Support if you receive this message.
Upgrading rmw
areonanedgeswitchfrom04.xx.xxto05.xx.xx
An issue has bee
nidentied in release 04.xx.xx if the co ntents of the nonvolatile storage
(NVRAM) on the
CTP become corrupted. Once the con guration has be en loaded,
this corrupt
ion is not detected until an IPL/IML, power cycle, or rmware code load.
If the NVRAM in the CTP has corrupted contents, the rmware load can cause the
conguration to reset to factory defaults, which could cause a system outage.
Edge switch p
roducts already running 05.01.00 or later continually validate the NVRA M
congurati
on, so risk of an outage is extremely low. For edge switch products running an
earlier ver
sion of rmware, the risk of an outage increases due to the NVRAM issue. If
an outage c
ompromises system integrity, H P recommends that the edge switch rmware
upgrade b
e a scheduled maintenance action that anticipates the failure of switch
connect
ivity. This issue was corrected with rmware 05. 02.00-13 and later.
To safely upgrade rmware on a edge switch, per form the following:
1. Upgrade HA FM software on the HA FM server/appliance to 07.01.00 (minimum) .
2. Download rmware 05.02. 00-13 using the Firmware Library option under the
Product Manager Maintenance menu.
3. Backuptheedgeswitchconguration using the Backup & Restore Conguration
optio
n under the Product Manager Maintenance menu.
4. Upgr
ade the rmware to 05.02.00-13 on each edge switch using the Send option
on the Firmware Library dialog box.
Considerations for downgrading the version of rmware
Directors or edge switches are not required to be ofinebeforeperformingarmware
downgrade o peration. Limitations to downgrades are clearly identied if there are any
limitations to performing the operation.
Before downgrading rmware, it is highly recommended tha t you back up the director
or edge switch conguration. Refer to your HP StorageWorks Edge Switch Element
ManagerUserGuidefor more information. EWS also provides an option to print or
save product conguration to a le. Refer to your HP StorageWorks Embedd ed Web
Server User Guide for more information.
10