disassembly/assembly
Removing and reinstalling the
main tray
CAUTION After you have lowered the
main tray, be sure to
unplug the power cord of
the MFP from the power
outlet.
Procedure
1 Push up the actuator of the main tray exit
with your finger to lower the main tray.
2 Turn the MFP's main power switch (SW1)
off, and unplug the power cord from the
power outlet.
3 Remove the two mounting screws.
4 Lift the main tray and detach it from the
hooks of the up/down stay.
5 Reinstall the above parts following the
removal steps in reverse.