A SERVICE OF

logo

User manual - SR150 2-CHANNEL UNIVERSAL POWER AMPLIFIER | P 9
8
MAINTENANCE
The GOLDMUND SR150 amplifier usually requires no maintenance.
To clean your SR150 use a very soft, clean, damp cloth to avoid scratching the surface.
Dampen with water or a mild detergent solution. Avoid abrasive or harsh cleansers (eg.
products containing sodium carbonate). Always turn the power off before cleaning your
amplifier.
TECHNICAL DATA
POWER
• Nominal power before clipping: 2x200 W RMS (2 - 8 Ohms). 150 W RMS (1 - 16 Ohms).
• Maximum power : > 400 W RMS (3 Ohms).
• Maximum voltage : 55 V peak. - Maximum current : > 15 A peak.
These values are for both driven channels.
FREQUENCY RESPONSE
These figures are valid for the circuit alone, at any level between 0 and nominal power.
• +/- 0.1 dB, 10 Hz - 1 MHz.
• +/- 1 dB, 6 Hz - 1.2 MHz.
• +/- 3 dB, 3 Hz - 1.4 MHz.
ANALOGUE INPUT SENSITIVITY
Nominal level : 0.75 V.
• Input impedance : 50 kOhms.
GROUP DELAY
Propagation delay < 1
00 ns stable with frequency from DC to 2
00 kHz.