INSTALLATION INSTRUCTIONS
57
Safety Instructions for the Installer
• Legal regulations and the local electricity board’s requirements for
making connections must be observed in full.
• When connecting, repairing and replacing the oven light bulb, isolate
the appliance from the electricity supply.
Installation instructions
• Full protection against electric shocks must be ensured by the
method of installation.
• The protective conductor must be long enough so that, if the strain
relief device fails, it is not subjected to tension until after the live
conductors of the connection cable.
• If you want to install the oven in the corner of an L-shaped kitchen
so that the left side of the oven is flush with the other kitchen line,
there must be a space of at least 15 cm between the left side of the
oven and the other line front.
• In accordance with heating testing standards, the appliance corre-
sponds to Safety Class Y.
• The furniture into wich the oven is to be installed must be tempera-
ture resistant to 100°C. This applies in particular to veneer, edging,
plastic surfaces, adhesives and lacquers. The fronts of the surrounding
furniture must be temperture resistant to at least 70°C.
• The appliance is to be installed flush with the wall. The appliance
mains socket must therefore be located outside the installation area.
• It is imperative to install the appliance horizontally on an even sur-
face. This surface must not bend.
• If the furniture unit is not attached to the wall, attach it using a con-
ventional fixing angle.
!