5–131
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
PARTITION=partition_number
Identifies the unit number for a partition on a container. The partition-number
identifies the partition associated with the unit number being added. Use the SHOW
container-name command to find the partition numbers used by a storageset or a
single-disk unit.
NOTE: Do not split partitioned units across ports. Partitioned units must be on a
single port.
MAXIMUM_CACHED_TRANSFER=n
MAXIMUM_CACHED_TRANSFER=32 (Default)
The controller does not cache any transfers over the set size. Accepted values are 1
through 2048.
PREFERRED_PATH=OTHER_CONTROLLER
PREFERRED_PATH=THIS_CONTROLLER
NOPREFERRED_PATH (Default)
May be set only when dual-redundant controllers are operating in a multiple bus
failover configuration. In a multiple bus failover configuration, the host determines
which controller the units are accessed through. The host’s unit-to-controller settings
always take precedence over the preferred path assigned to units with this switch. The
target ID numbers assigned with the SET controller PORT_1_ID (or PORT_2)
command determines which target ID number the controller uses to respond to the
host.
NOTE: When the controllers are configured to operate in transparent-failover
mode, if you set the PREFERRED_PATH switch with the ADD UNIT or SET
unit-
number
command, an error message displays because you can only assign a
preferred controller path at the unit level only when in multiple bus failover mode.
When no preferred path is assigned, the unit is targeted through the controller which
detects the unit first after the controllers start.