![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/a/d9/ad9d61fe-2289-4cb3-ba5b-13d0c6afad8a/ad9d61fe-2289-4cb3-ba5b-13d0c6afad8a-bg7.png)
6
6. Hooking up the Pump
6.1 INSTALLATION OF PUMP
• The pump should be set inside a covered area on a level surface such as a stage or
platform. Do not set it on a soft surface as the vibration will sink the unit.
6.2 WATER SUPPLY
• Insure that the water source being used can supply enough water for the demand of
the pump. Use a minimum ¾” hose (19 mm) with at least 40 PSI (2.8 bar) of clean
water.
6.3 WATER FILTER INSTALLATION
• NOTE! Use factory-supplied water filter in water supply to the pump. Contaminants
in water can damage pump and plug nozzles if filter is not used!
Drain
IN
Bucket
• Connect the water supply line to the CITC filter assembly (mount near the pump,
possibly on frame of a dolly or a wall if permanently installed). Simply connect the
hose to the filter.
• Before connecting to pump, run water through the hose, then the CITC filter for thirty
seconds to flush the line and avoid any contaminants entering the pump, then
connect the 3-foot long tubing from the filter to the “IN” connection on the pump.
Note! Filter must be in upright position (per diagram) to prevent airlock.
• If using a new hose, rinse the hose for ½ hour to flush out odors.