MCS-D 200 Control Unit
E
36
3.3.10 DAI/DDI Management
The MCS-D 200 control unit features an integrated D/A interface (=INTERNAL DAI) with the connexions CH1 IN, CH2 IN,
CH1 OUT and CH2 OUT.
To provide more analogue inputs and outpus, additional Digital / Analog Interfaces (DAI) are connected via the conference
bus for the connection of external audio devices such as wireless microphones or tape recorders providing the sound of a
video film in different languages. The 19" housing of a Digital / Analog Interface (DAI) may be equipped with a maximum of
3 interface units (=EXTERNAL DAI), each with 2 analogue audio inputs and outpus. The DAI is powered via the system and is
recognised when the system is started.
In the DAI/DDI MANAGEMENT menu you can set the following:
DAI Management:
• Set an identification number (logical address) for each external DAI.
• Assign channels to the LINE INPUTS and LINE OUTPUTS of the internal and external DAIs.
DAIs are operated as described in the following:
• Set the level of all LINE IN and LINE OUT channels of the internal and external DAIs.
• Switch on/off all LINE IN and LINE OUT channels of the internal and external DAIs.
Warning:
Unused DAI inputs must be OFF, to avoid noise!
DDI Management:
• Assign channels to digital outputs
DDIs are operated as described in the following:
• Switch on/off all outputs.
The DAI/DDI Management menus include the Ext. DEVICE LIST, DAI SETUP and DAI CONTROL menus.
Use the up or down navigator button for
scrolling
press the ENTER button