13
■
Connections
M1
M2
M3
M4
M5
M6
M7
M8
D1
D2
MX1 MX3
ID
1
2
MX2
D3
D4
D5
D6
D7
D8
P1 P2 P3 P4 L1 L2 L3 L4
MASTER STATION
IS-CCU
DC48V
VIDEO/AUDIO DOOR/SUB STATION
PA OUTPUT (600Ω)
VIDEO OUTPUT
CONTACT OUTPUT (AC/DC24V 0.5A)
V1 V2
CAT5e/6
300m
(980')
CAT5e/6
300m
(980')
15m(50')
200m
(650')
CAT5e/6
150m
(490')
Coax
15m (50')
NTSC
15m (50')
NTSC
*1
D
C
2C
M
1MX1 1MX2 1MX3
Coax
PT
*2
φ0.8-1.2mm
(20-16 AWG)
CAT5e/6 (x3)
BNC
connector
BNC
connector
BNC
connector
BNC
connector
P
NP
2C
φ0.65-1.2mm
(22-16 AWG)
15m (50')
NP
2C
φ0.65-1.2mm
(22-16 AWG)
NP
2C
φ0.65-1.2mm
(22-16 AWG)
*1: This connection is needed when a PA amplifi er that needs a trigger input is connected. (Up to AC/DC 24V 0.5A)
*2: Do not install two power supplies in parallel to a single input. Be sure to connect a single power supply unit to a control unit.
*3: Setting the ID setting switch
ID No. Switch position Description
ID 1
ON
OFF
Set to this position when this unit is connected to 1MX1, 1MX2 and 1MX3 ports of IS-CCU.
ID 2
ON
OFF
Set to this position when this unit is connected to 2MX1, 2MX2 and 2MX3 ports of IS-CCU.
*4: Refer to “Output specifi cations” (→P.11).
NOTES:
Do not use the unoccupied terminals and ports for other purposes.
•
In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
•
For connecting other manufacturer’s products, refer to the instruction manuals for those products.
•
The illustration of the unit’s front panel differs from the actual one. This is for simplifying the connection diagram.
•
Door station
(IS-DV/IS-DVF/
IS-SS)
Power supply unit
(IS-PU-UL/IS-PU-S)
Master station
(IS-MV)
Central control unit
(IS-CCU)
Room sub station
(IS-RS)
ID setting switch
*3
Contact output *4
(Electric door strike, strobe light, etc.)
Monitor 1,
Recorder 1
Monitor 2,
Recorder 2
or
(non-shielded)
(non-shielded)
(non-shielded)
(non-shielded)
AC
transformer
PA output
(50mVrms, 600Ω)
PA amplifi er
NP: Non-polarized
P: Polarized