A SERVICE OF

logo

490
S:\agilent\8920\8920b\PRGGUIDE\BOOK\CHAPTERS\callproc.fb
Chapter 8, Programming the Call Processing Subsystem
CALL BIT Screen Message Field Descriptions
E
This field displays the extended address word sent to the mobile.
Set to ‘1’ if the extended address word is sent.
Set to ‘0’ if the extended address word is not sent.
1 binary character required.
REGH
Registration field for home stations.
1 binary character required.
REGR
Registration field for roaming stations.
1 binary character required.
DTX
Discontinuous transmission field.
2 binary characters required.
N-1
N is the number of paging channels in the system.
5 binary characters required.
RCF
Read-control-filler field.
1 binary character required.