Wegener Communications Unity Satellite Receiver Model Unity Synchronous Data Option Satellite Radio User Manual


 
3 UTY4000-007
2.2 Customer Premises Wiring
Outputs supplied on two RJ45 jacks. Pins are numbered (left-to-right) 1 to 8 as seen
from the open end with tab facing downward.
PIN# LVDS SIGNAL
OUTPUT
RS422 SIGNAL
OUTPUT
1 GND GND
2 LD+ RD+
3 LD- RD-
4 LS+ RS+
5 LS- RS-
6 LC+ RC+
7 LC- RC-
8 GND GND
Table 1. RJ-45 Pin-outs
3. CONTROL AND STATUS INDICATIONS
Note: Sync Data option card may be setup by your network and local control may be disabled. If
so, only the status monitoring will be possible.
3.1 From Terminal
Ÿ Sync data card setup with local control disabled:
The sync data card setup cannot be accessed via the terminal with local control
disabled. Local control will have to be authorized by the network.
Ÿ Sync data card setup with local control enabled :
CSD cmd param port
Cmd: R - Set RS422 output state
L - Set LVDS output state
D - Set data rate
P - Set PID
Param:E/D - Enable/disable output ports (used with R & L commands)
64.0 - 6875 Kbps - data rate range (used with D command)
0x0020 - 0x1FFE - PID range (used with P command)
Port: port number (1 or 2)
Ÿ Sync data card status