Vestax PDX-2000MkII, PDX-2000MkII Pro Turntable User Manual


 
9
In case of the height of Tone-Arm is needed for adjustment, it is
possible to adjust the height by following the scale of Tone-Arm
Height Gauge after loosening the Tone-Arm Height Fixed Screw.
The adjustment range is 9mm at the maximum.
Cartridge height 16mm
Cartridge height 25mm
Rotate
this part
Balance Weight
Counter Ring
Rotate
this part
Balance Weight
Counter Ring
Tone-Arm Height Fixed Screw
Tone-Arm Height
Gauge
In case the balance weight moved, do the adjustment
of horizontal zero balance again.
The appropriate stylus pressure needs to be set in
order to generate the best performance. Please refer
to the user’s manual of the stylus.
Be sure to tighten the Tone-arm height Fixed screw well.
The stylus may jump/skip if the height setting is not
secured.
qHold the balance weight with one hand as shown in the
drawing, and rotate only counter ring to bring the numeral "0"
of the ring into alignment with the center line on the tone-arm
rear shaft.
wTurn the balance weight to present the reading on the gauge to
the designed stylus force of your cartridge.
As counter ring moves in step with the balance weight, proper
stylus pressure can selected by reading the
graduated ring directly.
Adjustment of Tone-arm Height
Adjustment of Stylus Puressure
qLoosen the dynamic needle pressure adjustment knob and pull
it to the position with appropriate needle pressure, the tighten
the knob.
Dynamic Needle Pressure
Adjustment Knob
Loose Close
Dynamic Needle
Pressure
Adjustment Knob