6. Reinstatement is a simple reversal of the above process. Reconnect the compression driver cables, observing the correct
polarity (white cable to the +ve terminal, green/white cable to the –ve terminal).
7. Replace the horn and driver in the cabinet.
8. Replace the horn fixing screws and tighten.
9. Reconnect the bass driver cables, observing the correct polarity (brown cable to the red +ve terminal, blue cable to the black –ve
terminal) and reinstate the driver in the cabinet. Replace and tighten the driver fixing screws.
10. Replace the grille (fig 6) and phase check the cabinet before use.
Rotating the HF horn pattern
The high frequency horn in all TCX two-way models can be rotated through 90° in order to swap the horizontal and vertical
dispersion patterns, particularly useful to retain the wide horizontal dispersion when the cabinet is installed horizontally in venues
with limited ceiling height.
1. Remove the loudspeaker grille as above.
2. Remove the M5 hex head HF horn fixings screws
3. Lift the horn / driver assembly out, rotate the horn as necessary to achieve the desired coverage pattern and replace it in the
cabinet.
4. Replace the horn fixing screws and tighten.
5. Replace the grille and phase check the cabinet before use.
EASE Data
EASE data is available for TCX series loudspeakers to enable software simulation of audio coverage installation projects. Please
visit ftp://ftp.turbosound.com for a free EASE data download.