Texas Instruments TAS5508-5121K8EVM Stereo Amplifier User Manual


 
Device Fault Reporting
3-3
Protection
3.2 Device Fault Reporting
The OTW and SD outputs from the TAS5121 indicate fault conditions. See the
TAS5121 data sheet (SLES086) for a description of these pins.
The temperature warning signals at the TAS55085121K8EVM board are
wired-OR to one temperature warning signal [OTW
– pin 22 in control interface
connector (J30)].
Shutdown signals are wired-OR into two shutdown signals [SD1
and SD2 – pin
20 and pin 21 in control interface connector (J30)]. See Table 31 for channel
allocation.
Table 31. Channel Allocation
Description Terminal Shutdown Signal
Front left J100 SD1
Front right J200 SD1
Rear left J300 SD2
Rear right J400 SD2
Surround left (or line out left) J500 SD2
Surround right (or line out right) J600 SD2
Center J700 SD1
Subwoofer J800 SD2
The shutdown signals, together with the temperature warning signal, give chip
state information as described in Table 32. Device fault reporting outputs are
open-drain outputs.
Table 32. TAS5121 Warning/Error Signal Decoding
OTW SDx Device Condition
0 0 High-temperature error and/or high-current error
0 1 High-temperature warning
1 0 Undervoltage lockout or high-current error
1 1 Normal operation, no errors/warnings