Sony HTSS2000 Home Theater System User Manual


 
28
GB
D:\CANNES\SONY_HA\JOB 2007\HT-SS2000\IM_SS2000\Data_CEL\Data_GB\GB03CON_HT-
SF2000-CEL.fm
masterpage: Left
[HT-SF2000/HT-SS2000]
3-210-806-11
(2)
2 Press V/v repeatedly to select
the item. Then, press .
3 Save the measurement result.
Select “SAVE” in step 2.
The measurement results are saved.
When error codes appear
Try the remedies and perform the Auto
Calibration again.
To rectify the error
1 Record down the error code.
2 Press , “RETRY Y” appears on the display.
3 Rectify the error.
For details, see “When error codes appear”
above.
4 Press to perform Auto Calibration again.
When you select “WARN CHK”
If a warning on the measurement result is
present, detailed information is displayed.
Press to return to step 2 of
“Confirming/saving the
measurement results”.
Item Explanation
RETRY Performs the Auto
Calibration again.
SAVE Saves the measurement
results and exits the setting
process.
WARN CHK Displays warning
concerning the
measurement results. See
“When you select “WARN
CHK”” (page 28).
PHASE Displays the phase of each
speaker (in phase/out of
phase). See “When you
select “PHASE”” (page 29).
DISTANCE Displays the measurement
result for speaker distance.
LEVEL Displays the measurement
result for speaker level.
EXIT Exits the setting process
without saving the
measurement results.
Error code Cause and remedies
ERROR 32 None of the speakers were
detected. Make sure that the
optimizer microphone is
connected properly and perform
the Auto Calibration again.
If the optimizer microphone is
connected properly but the error
code appears, the optimizer
microphone cable may be
damaged or improperly connected.
ERROR F 33 None of the front speakers are
connected or only one front
speaker is connected.
The optimizer microphone is not
connected.
ERROR SR 33 Either the left or right surround
speakers is not connected.
ERROR SW 33 Sub woofer is not connected.
Connect the sub woofer to the
SUBWOOFER terminal.
ERROR 33 Wrong speaker detection due to
noise. Make sure the environment
is quiet during Auto Calibration.
Warning code Explanation
WARN 40 The Auto Calibration has
completed. However, the noise
level is high. You may be able to
perform the Auto Calibration
properly if you try it again, even
though the measurement cannot be
performed in all environments. Try
to perform the Auto Calibration in a
quiet environment.
WARN 41 The sound input from the
optimizer microphone is out of
the acceptable range. It is louder
than the loudest sound that can be
measured. Try to perform the
Auto Calibration when the
environment is quiet enough to
allow proper measurement.
WARN 42 The volume of the receiver is out
of the acceptable range. Try to
perform the Auto Calibration
when the environment is quiet
enough to allow proper
measurement.
Error code Cause and remedies