Technical Data
Headphones HME 26-100 (4) HME 26-600 (4)
Transducer principle
dynamic, closed dynamic, closed
Ear coupling
supra-aural supra-aural
Frequency response
20 – 18,000 Hz 20 – 18,000 Hz
Impedance
50 O mono/100 O stereo 300 O mono/600 O stereo
THD
< 0,5 % at 1 kHz < 0,5 % at 1 kHz
Nominal SPL
105 dB SPL at 1 kHz, 1 mW
115 dB SPL at 1 kHz, 1 V
(ActiveGard™ switched off)
105 dB SPL at 1 kHz, 1 mW
107 dB SPL at 1 kHz, 1 V
(ActiveGard™ switched off)
Max. SPL
105 dB SPL at 1 kHz
128 dB SPL at 1 kHz, 200 mW
(ActiveGard™ switched off)
105 dB SPL at 1 kHz
127 dB SPL at 1 kHz, 200 mW
(ActiveGard™ switched off)
Contact pressure
approx. 3.6 N approx. 3.6 N
Microphone
Type
BKE 4-4 cardioid BKE 4-4 cardioid
Transducer principle
pre-polarized
condenser microphone
pre-polarized
condenser microphone
Frequency response
40 – 20,000 Hz 40 – 20,000 Hz
Output voltage
4 mV/Pa ± 2.5 dB 4 mV/Pa ± 2.5 dB
Terminating impedance
min. 4,7 kO min. 4,7 kO
Supply voltage
5 V – 15 V DC 5 V – 15 V DC
General Data
Weight without cable
approx. 200 g approx. 200 g
Packaging
Individual package dimensions
194 mm x 84 mm x 249 mm 194 mm x 84 mm x 249 mm
Master carton dimensions
512 mm x 252 mm x 382 mm 512 mm x 252 mm x 382 mm
Units per master carton
12 12
Languages
German, English, French, Italian,
Spanish, Dutch, Russian
German, English, French, Italian,
Spanish, Dutch, Russian
Product versions
Model Item no. Description Cable, length 2 m
HME 26-100 (4)
504203 100 O per system, condenser
microphone cardioid
HME 26-600 (4)
504204 600 O per system, condenser
microphone cardioid
HME 26-100
502454 100 O per system, condenser
microphone omni-directional
HME 26-100-7
502455 100 O per system, condenser
microphone omni-directional
steel wire
cable with
open ends
HME 26-600
502467 600 O per system, condenser
microphone omni-directional
HME 26-600-7
502468 600 O per system, condenser
microphone omni-directional
steel wire
cable with
open ends
HME 26-600 S
502469 600 O, one side, condenser
microphone omni-directional
Model Item no. Description Cable, length 2 m
HMD 26-100
502451 100 O per system,
dynamic microphone cardioid
HMD 26-100-7
502452 100 O per system,
dynamic microphone cardioid
steel wire cable
with open ends
HMD 26-600
502463 600 O per system,
dynamic microphone cardioid
HMD 26-600-7
502464 600 O per system,
dynamic microphone cardioid
steel wire cable
with open ends
HMD 26-600 S
502465 600 O, one side,
dynamic microphone cardioid
HMD
26-600-X3K1
502466 600 O per system,
dynamic microphone cardioid
steel wire cable
with XLR-3
connector and
6.3 mm jack plug
HMDC 26-600
502453 NoiseGard™, 600 O per system,
dynamic microphone cardioid