Samson SXD3000 Home Theater System User Manual


 
10
Getting Started - DSP
EQ - In Manual mode there are three EQ filters per channel. The Low frequency adjustment can be set to a Low Frequency
Shelf or to a parametric equalizer (PEQ) with Frequency, Q, and Gain adjustments. The mid band is a parametric equal-
izer (PEQ) with Frequency, Q, and Gain adjustments. The high frequency band can be set to a High Frequency shelf or to
a parametric (PEQ) band. Press the Edit button to enter the EQ parameters. If Ch A EQ is set ON, Ch B can be set to the
same settings by choosing A=B. If using a speaker preset, the SXD offers seven EQ preset frequency curves to match your
performance setting: DJ, Vocal, Live Sound, Install, Rock, Dance, Jazz.
Limiter - The limiter provides additional protection to your speakers from overload. Press the EDIT button to adjust. The
Limiter can be set to -1dB, -3dB, and -9dB.
Delay - The delay time can be used to align speakers in a system. This is useful when using a subwoofer and satellite
speaker for front of house to ensure the speakers are in phase for optimal performance. Click the Edit button to adjust. The
Delay settings are displayed in milliseconds, inches/feet, and centimeters/meters.
Setup - In the Setup mode the amplifier can be locked and the user can create a four-digit code so settings are not acci-
dentally changed. Click to set Lock Code. Rotate the EDIT knob to adjust the code number, and press the DOWN and UP
buttons to move through each digit. Click the EDIT button to set the lock code.
If you have forgotten your Lock Code, you can reset it by turning off the amplifier, then while holding the UP and DOWN
buttons turn the power back on.
Factory Reset - This sets all parameters and presets back to the original factory default settings.