Pico Macom PIDA-1000 Stereo Amplifier User Manual


 
PICO MACOM, INC.
12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028 • (800) 421-6511 • FAX (818) 834-7197
PCB Plug-In Module and Jumper Locations
4
FOWARD PATH INPUT
RETURN PATH OUTPUT
-30dB INPUT
TEST POINT
RETURN PATH INPUT
FOWARD PATH OUTPUT
-30dB OUTPUT
TEST POINT
PIDA 550/750/1000
FOWARD
ATTENUATOR
EQUALIZER
W3
W2
W6
W10
W5
W8
JUMPERS W5 AND W6
INSERTED FOR ACTIVE
RETURN PATH
REMOVE JUMPERS W6 AND
W5 AND INSERT JUMPER
BETWEEN THESE TWO POINTS
FOR PASSIVE RETURN PATH
PLUG-IN LOCATION
FOR EQUALIZER*
(FORWARD PATH)
PLUG-IN LOCATION
FOR ATTENUATOR*
(FORWARD PATH)
PLUG-IN LOCATION
FOR ATTENUATOR*
(RETURN PATH)
SLOPE CONTROL
(FOWARD PATH)
GAIN CONTROL
(FOWARD PATH)
GAIN CONTROL
(RETURN PATH)
*NOTE:
PLUG-IN EQUALIZERS AND ATTENUATORS ARE OPTIONAL.
IF PLUG-INS ARE TO BE USED REMOVE JUMPER WIRE AT
APPROPRIATE LOCATION AND INSERT PLUG-IN.
D E S C R I P T I O N S