Philips BGY88 Stereo Amplifier User Manual


 
1997 Apr 09 3
Philips Semiconductors Product specification
CATV amplifier module BGY88
CHARACTERISTICS
Table 1 Bandwidth 40 to 450 MHz; T
mb
=35°C; Z
S
=Z
L
=75
Notes
1. f
p
= 55.25 MHz; V
p
= 46 dBmV;
f
q
= 343.25 MHz; V
q
= 46 dBmV;
measured at f
p
+f
q
= 398.5 MHz.
2. Measured according to DIN45004B;
f
p
= 440.25 MHz; V
p
=V
o
= 62 dBmV;
f
q
= 447.25 MHz; V
q
=V
o
6 dB;
f
r
= 449.25 MHz; V
r
=V
o
6 dB;
measured at f
p
+f
q
f
r
= 438.25 MHz.
3. The module normally operates at V
B
= +24 V, but is able to withstand supply transients up to +30 V.
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
G
p
power gain f = 50 MHz 33.5 35.5 dB
f = 450 MHz 35 37 dB
SL slope cable equivalent f = 40 to 450 MHz 0.5 2.5 dB
FL flatness of frequency response f = 40 to 450 MHz −−±0.3 dB
S
11
input return losses f = 40 to 80 MHz 20 −−dB
f = 80 to 160 MHz 19 −−dB
f = 160 to 450 MHz 18 −−dB
S
22
output return losses f = 40 to 80 MHz 20 −−dB
f = 80 to 160 MHz 19 −−dB
f = 160 to 450 MHz 18 −−dB
CTB composite triple beat 60 channels flat; V
o
= 46 dBmV;
measured at 445.25 MHz
−−−58 dB
X
mod
cross modulation 60 channels flat; V
o
= 46 dBmV;
measured at 55.25 MHz
−−−59 dB
d
2
second order distortion note 1 −−−70 dB
V
o
output voltage d
im
= 60 dB note 2 62 −−dBmV
F noise figure f = 450 MHz −−6dB
I
tot
total current consumption DC value; V
B
= +24 V; note 3 320 340 mA