Problem
Possible cause
Remedy
No sound /power
Volume not adjusted
Adjust the VOLUME
Power cord not securely connected
Connect the AC power cord properly
Batteries dead/ incorrectly inserted
Insert (fresh) batteries correctly
CD contains non-audio files
Press
, §
once or more to skip to a CD audio
track, instead of the data file.
Display does not function properly / No reac-
tion to operation of any of the controls
Electrostatic discharge
Switch off and unplug the set.Reconnect after a
few seconds
---, Er
or
no indication
No CD inserted
Insert a CD
CD badly scratched or dirty
Replace/ clean CD, see Maintenance
Laser lens steamed up
•Wait until lens has cleared
CD-R/CD-RW is blank or not finalized
Use a finalized CD-R/CD-RW or suitable CD
Audio disc only
Note:
Make sure the CD is not encoded with copy-
right protection technologies, as some do not
conform to the Compact Disc standard.
The CD skips tracks
CD damaged or dirty
Replace or clean CD
Program/shuffle is active
Quit program/shuffle mode
Note: A CD badly scratch or dirty may result in
improper operation.
Sound skips during MP3 playback
MP3 file made at compression level exceeding
320kbps
Use a lower compression level to record CD
tracks into MP3 format
Disc damaged or dirty
Replace or clean disc
The USB device doesn’t play on my
AZ1839
It is not set in the USB mode.
Select the USB
mode
.
The device is not securely connected to AZ1839’s
USB port.
Re-connect the device, and make sure that the
device is powered on.
The device is not supported by AZ1839, or the audio
file format stored on the device is not supported by
AZ1839.
Use a compatible device/ playable audio file
format.
Troubleshooting
If a fault occurs,first check the points listed below before taking the set for repair.
If you are unable to remedy a problem by following these hints,consult your dealer or service centre.
WARNING:
Do not open the set as there is a risk of electric shock.Under no
circumstances should you try to repair the set yourself,as this will
invalidate the guarantee.