Phase Technology RS500i Speaker User Manual


 
Technical data, EASE
plots, SoundTubeSPEC
software & product downloads available at www.soundtube.com
RS500i
Open-Ceiling Speaker
Technical Information for System Engineers
Applications
Designed for indoor & outdoor back-
ground to mid-level SPL applications,
the RS500i includes a single-point
mounting system for rapid open-ceiling
installations. The 100° broad dispersion
pattern (55 Hz – 10 kHz) and high sensi-
tivity (88.5 dB 1W/1M) make the RS500i
speaker ideal for music & paging appli-
cations in retail, grocery stores, restau-
rants, hotels, casinos, museums, trade
shows & conference rooms. For applica-
tions where additional bass is required,
SoundTube’s RS801i 8” subwoofer pro-
vides bass down to 40 Hz.
BroadBeam
®
Wide
Dispersion Technology
More than 3 years in development,
SoundTube’s proprietary BroadBeam
®
technology incorporates a high-fre-
quency waveguide mated to a 1” convex
aluminum tweeter. The BroadBeam
®
high-frequency waveguide delivers a
consistent 100°
dispersion pattern across
the upper registers of the frequency
spectrum (up to 10 kHz, EASE
docu-
mented). The result is an audio system
with fewer speakers, reduced power
needs, shorter installation time and cost
savings on shipping & labor.
Patented SoundTube
Technologies
SoundTube Entertainment is constantly
developing new technologies that enhance
audio product performance. SoundTube
Entertainment innovations are protected
by multiple U.S. & international patents,
which explicitly cover SoundTube
dispersion, enclosure & dome technolo-
gies. SoundTube Entertainment actively
defends its patents in order to protect
SoundTube resellers and end users.
Technical Data and
Specification Tools
Technical Data
SoundTube Entertainment strives to
provide complete and effective techni-
cal information and data to dealers,
engineers and designers. All data are
available from SoundTube Entertain-
ment or at www.soundtube.com.
Data Acquisition
All performance data acquired at
SoundTube’s Technical Measurement
Center (TMC) are analyzed using a vari-
10,000 Hz
8,000 Hz4,000 Hz
2,000 Hz
1,000 Hz
500 Hz250 Hz
125 Hz
ety of standard measurement techniques,
including Measured Length Sequence
(MLS) and Time Delay Spectrometry
(TDS). Performance, development and
data acquisition tools include: Gold Line
TEF 20, CLIO, LMS, LEAP, and propri-
etary modeling software. EASE
data are
acquired through an automated TEF20/
Outline/EASE
interface.
EASE™ Data
– 3-D polar plots.
SoundTubeSPEC™
– Proprietary
SoundTube speaker placement software.
Architectural Specifications
The loudspeaker shall consist of a 133
mm (5.25 in) low-frequency transducer
and a 25 mm (1.0 in) high-frequency trans-
ducer with a crossover installed in the
ported enclosure. The low-frequency voice
coil diameter shall be 25 mm (1.0 in).
Performance specifications of a typi-
cal production unit shall be as follows:
Useable frequency response shall extend
from 55 Hz – 22 kHz (-10 dB, half space,
no external equalization). Measured
sensitivity (2.83 Volt input, 1 meter) shall
be at least 88.5 dB. The speaker shall
have a nominal impedance of 8 Ohms
and be available for 25, 70.7 & 100 Volt
Polar Plots